Mechatronics Eurosens DPS A (RS, CAN) converter

    

Eurosens DDS converts the air pressure in the output voltage or digital messages via serial RS485 or automotive CAN bus J1939 protocol. As the pressure transducer thin-film bridge is used.

Eurosens DPS A output :

Pressure, Mpa

The output voltage, V

0

0,25

0,1

0,70

0,2

1,20

0,3

1,55

0,4

2,00

0,5

2,50

0,6

2,95

0,7

3,30

0,8

3,80


Eurosens DPS RS uses LLS/MODBUS protocol

Eurosens DPS CAN uses CAN bus J1939 protocol with configurable PGN.

After installation and wiring Eurosens DPS should perform a calibration in which you are mapping the output signal to the load on the suspension of the vehicle.