MEMFlo™ Universal MFT2 2-Wire, Flocorp-Flow Transmitter

MEMFlo™ Universal MFT2 2-Wire Flow Transmitter


Flow transmitters are typically bundled with flow meters resulting in maximized performance. Flow transmitters transmit the flow value data in order to monitor the application or system. Technologies offered include variable area, positive displacement, and fiber optic.

The MFT2™ two-wire flow transmitter accurately calculates and outputs flow rate. Compatible with any MEMFlo variable area flow meter, MFT2™ combines FLO-CORP’s time-proven variable area technology with a high tech processor and solid state circuitry. Each device includes an analog output that can be configured for 0-5 VDC, 0-10 VDC, or 4-20 mA current loop. Typical applications include pump flow output, compressed air consumption, cooling flow monitoring, steam flow usage/optimization and combustion gas metering.

Features and Benefits

  • Non-contact sensor electronic
  • Electronic signal conditioning circuit
  • 3 output modes: 4-20mA, 0-5 VDC or 0-10 VDC
  • Proportional analog output - two-wire, 4-20mA
  • Designed to slip over any standard measuring tube
  • Pre-calibrated from the factory for fast installation and start-up
  • Optional Epoxy Coated Aluminum Enclosure for durable, rugged applications

Specifications

General

 

Process Temperature

F: -20º to 240º C: -29º to 116º

 

Ambient Temperature

F: -20º to 158º C: -29º to 70º
EnvironmentalHumidity: 0-90% non-condensing
Accuracy±1% 0.25% rate
Repeatability±0.10% rate
Electrical

 

 

Power Requirements

 

0.5 VDC Output 10-30 VDC @ 3 wire 0-10 VDC Output 12-30 VDC @ 3 wire

4-20 mA Output loop-powered, 12 VDC - 30 VDC - 2 wire

Power Consumption25 mA maximum

 

 

Analog Outputs

0-5 VDC and 0-10 VDC into 10,000 Ohms minimum;

4-20 mA into 1000 Ohms maximum

Resolution1:4000

 

 

Transmission Distance

4-20 mA limited by cable resistance (4000’)

0-5 VDC 1000 feet (330m) maximum

0-10 VDC 1000 feet (300m) maximum

Circuit ProtectionReverse polarity and current limiting
Isolation

Inherently isolated from the piping

system

Transient Over-VoltagesCategory 3, in accordance with IEC 64
Temperature Drift50 ppm/ºC (Max)
Enclosure RatingNEMA 4 (IP67) ; NEMA 7, Aluminum

We’ve been doing this long enough that there’s no surprises. Every problem has a solution, even when it takes shaking things up and rethinking the challenge. That’s our commitment: Find the right flow and level monitoring solutions for your specific needs. So you’re confident that your operations will consistently run efficiently, safely, and profitably.