Carbon monoxide binds with hemoglobin in the blood and causes toxic symptoms. It is colorless and odorless and cannot be detected by human senses with adverse effects directly proportional to concentration levels and length of exposure.
Sensitivity and accuracy are especially important for measuring carbon monoxide. GASTEC carbon monoxide detectors employ a highly sensitive controlled potential electrolysis method used for electrochemical analysis. It is able to accurately detect even the faintest amount of carbon monoxide.
Type of Carbon Monoxide gastec gas detector
1. CM-9A Gastec Carbon monoxide detector
Big Safety in Small body
Employs a highly sensitive controlled potential electrolysis method used for electrochemical analysis. It is able to accurately detect even the faintest amount of carbon monoxide.
- Small and lightweight, only 60g
- Low power consumption
- One-touch zero calibration of CO level, and span adjustment
- Incorporates a logging function.
Specifications
Measurement range | 0 - 300 ppm (enhanced range : 301 - 1999 ppm) |
---|---|
Measurement method | Controlled potential electrolysis method |
Sampling method | Diffusion |
Indicating accuracy | +/- 5% of full scale at time of calibration |
Operating Temperature / Humidity range | Temperature : -10 - 40 ℃ Relative humidity : 30 - 90 %RH |
Weight | 60g(including batteries) |
Dimensions | 77(W) x 21(D) x 42(H) mm(Excluding protrusions) |
Option
Gas Calibration KitCK-2/CK-10
This is a system for supplying calibration gas to the diffusion type sensor.
Precise and stable calibration can be accomplished by supplying calibration gas in the sampling bag at the rate that is most appropriate for the sensor.
Since the pump is compact and powered by dry cells, it does not require a special place for its use or storage.
Carbon monoxide sensor CO-60AE
Controlled potential electrolysis sensor
φ15 x 14 3g : CM-8A
2. CM-7B Gastec Carbon monoxide detector
Comes with a controlled potential electrolysis sensor.
A carbon monoxide detector employs a highly sensitive controlled potential electrolysis method used for electrochemical analysis. It is able to accurately detect even the faintest amount of carbon monoxide.
- Slim / Compact and lightweight, only 110g
- A simple auto-zero calibration procedure
- Explosion-proof
- Low power consumption
Specifications
Measurement range | 0 - 300ppm (enhanced range: 301 - 999ppm) |
---|---|
Measurement method | Controlled potential electrolysis method |
Sampling method | Diffusion |
Indicating accuracy | +/- 10% of full scale at the time of calibration |
Display | Digital LCD |
Explosion-proof | Certified by Japan Ministry of Health, Labour and Welfare (Class Ex ia ⅡC T3 Ga / Certification No.TC22574) |
Operating Temperature / Humidity range | Temperature : -10 - 40 ℃ Relative humidity : 30 - 90 %RH |
Power source | One AAA alkaline battery provides about 3500 hours of operation (when no alarm signal is emitted) |
Dimensions | 48(W) x 37(D) x 105(H) mm |
Weight | 110g |
Options
Sensor Extension CableGOA7H-10/GOA7H-11/GOA7H-12/GOA7H-13
Remote measurement of low oxygen concentration levels is essential for compliance with safety regulations against anoxia.
Available in lengths of 5m, 10m, 20m, 30m.
Gas Calibration KitCK-2/CK-10
This is a system for supplying calibration gas to the diffusion type sensor. Precise and stable calibration can be accomplished by supplying calibration gas in the sampling bag at the rate that is most appropriate for the sensor. Since the pump is compact and powered by dry cells, it does not require a special place for its use or storage.
Carbon monoxide sensor CO-604E
Controlled potential electrolysis sensor
φ19 x 31 7g : CM-6B / CM7B