dBMACH3 & dB3 with Double Sun Shields Pulsar Flow Transducers

 

dBMACH3 flow transducer

Pulsar's full range of ultrasonic transducers can be used for flow measurement however, there are two specific designs that have been specially created for flow applications.

The dBMACH3 is the first ultrasonic transducer with zero effective blanking distance.

Features for the dBMACH3 flow transducer

  • 0 - 2.425m measurement range (0 - 7.95ft)
  • ±1mm accuracy
  • ±0.5 resolution
  • IP68/NEMA 6P
  • ATEX Zones 1 & 2 approval standard. ATEX Zone 0 optional

dB3 with Double Sun Shields flow transducer

The dB3 with Double Sun Shields adds extra solar radiation protection to the transducer to ensure that the internal temperature compensation can be utilised.

  Another Article:

Features for the dB3 with Double Sun Shields flow transducer

  • 0.125 - 3m measurement range (0.41 - 10ft)
  • Accuracy: 0.25% or 6mm whichever is greater
  • Resolution: 0.01% or 2mm whichever is greater
  • IP68/NEMA 6P
  • ATEX Zones 1 & 2 approval standard. ATEX Zone 0 optional

Specifications

Transducer Specific

Model:dBMACH3dB3 with Double Sun Shields
Sensor body dimensions:180D (sunshield) x 205Hmm (7.08 x 8.07in)180D (sunshield) x 115Hmm (7.08 x 4.52in)
Sensor body weight:Nominal 1.1kg (2.4lbs)Nominal 1.1kg (2.4lbs)
Max. & min. temperature (electronics):

Standard: -30°C to +90°C (-22°F to +194°F)

ATEX: -30°C to +75°C (-22°F to +167°F)

Standard: -40°C to +90°C (-40°F to +194°F)

ATEX: -40°C to +75°C (-40°F to +167°F)

Measurement range:0 - 2.425m (0 - 7.95ft)0.125 - 3m (0.41 - 10ft)
Accuracy:±1mm (0.039in)0.25% or 6mm (0.24in) whichever is greater
Resolution:±0.5mm (0.019in)0.01% or 2mm (0.08in) whichever is greater
MCERTS certified:Not applicableClass 1 (0.193%) when used with FlowCERT Lite

Both Transducers

Physical

Sensor body material:Valox 357 U and syntactic foam face
Cable lengths:Standard = 5m, 10m, 20m or 30m (16.4ft, 32.8ft, 65.6ft or 98.4ft). Optional: up to 150m (492ft) maximum (increments of 10m / 32.8ft only)
Maximum separation:500m (1640ft)
Mounting connection:BSP or 1” NPT

Environmental

Enclosure protection:IP68 / NEMA 6P

Approvals

CE approval:2014/30/EU - EMC & 2014/34/EU ATEX Directives. Standards applied: EN 60079-0:2012+A11:2013/ EN 60079-11:2012 / EN 60079-18:2009 / EN 60079-26:2007 / EN 61326-1:2013
ATEX approval:Standard ATEX EEx m II T6 or optional EEx ia IIC T6. FM/FMC approval.

Performance

Frequency:125kHz
Beam Angle:<10°

Download Datasheet: dBMACH3 & dB3 with Double Sun Shields Pulsar Flow Transducers

References : pulsar-pm.com