IH5815 Siko Incremental Encoder

  • Robust optical standard rotary encoder
  • Resolution max. 5000 pulses/revolution
  • Through hollow shaft up to max. ΓΈ15 mm
  • Robust bearing construction
  • -40 °C … +85 °C operating temperature
  • High shock and vibration resistance

Specification

FeatureTechnical dataAdditional information
Shaftstainless steel 
Housingdie-cast 
Speed≤12000 rpmIP65
≤6000 rpmIP65 continuous operation
≤6000 rpmIP66/IP67
≤3000 rpmIP66/IP67 continuous operation
Moment of inertia~6 x 10-6 kgm2 
Starting torque<0.01 Nm at 20 °CIP65
<0.05 Nm at 20 °CIP66/IP67
Shaft load rating100 Nradial
50 Naxial
Cable sheathPVC∼ΓΈ6.7 mm
Cable bending radius75 mmstatic
110 mmdynamic
Weight~0.4 kg 

Electrical Data

PP Output Circuit

FeatureTechnical dataAdditional information
Operating voltage10 … 30 V DCreverse-polarity protected
Current consumptiontypical 50 mA≤100 mA (no load)
Output signal level high≥UB - 1.0 Vshort-circuit proof
Output signal level low≤0.5 Vshort-circuit proof
Pulse frequency≤300 kHz 
Load±20 mAmax. adm.
Type of connection1x M12 connector5-pole, 1x pin

OP Output Circuit

FeatureTechnical dataAdditional information
Operating voltage10 … 30 V DCreverse polarity protected
Current consumptiontypical 50 mA≤100 mA (no load)
Output signal level high≥UB - 1.0 Vshort-circuit proof
Output signal level low≤0.5 Vshort-circuit proof
Pulse frequency≤300 kHz 
Load±20 mAmax. adm.
Type of connectionopen cable end 
1x M23 connector12-pole, 1x pin

LD Output Circuit

FeatureTechnical dataAdditional information
Operating voltage5 … 30 V DCreverse-polarity protected
Current consumptiontypical 40 mA≤90 mA (no load)
Output signal level high≥2.5 Vshort-circuit proof, not against UB
Output signal level low≤0.5 Vshort-circuit proof, not against UB
Pulse frequency≤300 kHz 
Load±20 mAmax. adm.
Type of connectionopen cable end 
1x M23 connector12-pole, 1x pin

Signal Pattern

signal pattern

Ambient Conditions

FeatureTechnical dataAdditional information
Ambient temperature-40 … 85 °Cplug
 -30 … 85 °Cstatic laying of cables
 -20 … 85 °Cdynamic laying of cables
EMCEN 61326-1immunity requirement of industry
Protection categoryIP65, IP66/IP67EN 60529
Shock resistance3000 m/s2, 6 msEN 60068-2-27
Vibration resistance300 m/s2, 10 … 2000 HzEN 60068-2-6
Reference: siko-global.com