Flowma DMF-1 Series Coriolis Mass Flowmeter

Flowma DMF-1 is the integral and remote type Coriolis Mass Flowmeter. Both types have highly refined digital signal processing electronics, so that accurate and stable mass flow measurement is achieved. DMF-1 employs a flame-proof type converter case suitable for use in the hazardous area together with it’s intrinsically safety type detector.

DMF-1‘s signal processing, housing protection and its detector’s special decoupling system against external loads and vibrations, realize high perfeormance in real applications. Mass Flow Measurement according to the Coriolis principle. Almost all flowing materials including multi phase fluids, high viscosity liquids (pastes and slurries) and liquid with a certain content of gas. For difficult fluids (e.g. abrasive or highly corrosive fluids) and gases please contact your Beijing Sincerity representitave.

Flowma DMF-1 Series Coriolis Mass Flowmeter

Feature

  • Dual Symmetric, Differential Structure
  • High Sensitivity, High turn-down ratio
  • Non-linear Vibration, Suppression Technology
  • Smooth Flow designed for Anti-interference
  • Classic U-shape tube designed for High Sensitivity
  • All touch screen operation. The inner technical parameters can be modified by the touch screen
  • Engineer’s password and the operator’s password makes easy modification of the instrument
  • Power Supply:220VAC, 24VDC optional,with no distinguish of power terminal polarity
  • The latest V-shape design, with high stability, and pressure loss is minimal
  • Full digital closed-up controlling function and DSP digital processing circuit, realized the high stability and high two-phase flow measurement accuracy
  • Balance matching technology of the dynamic vibration improves the system stability.
  • Accurate control, specialized for the loading and unloading batch controlling occasions.

Technical Parameters

  • Field transmitter type mass flowmeter for nearly all fluids, including high viscosity liquids, slurries and multi phase media
  • Refined digital signal processing enables accurate and stable measurement
  • Simple flow path means self-draining, food capable and simple to clean
  • Choice of tube materials: Stainless Steel 316L, Hastelloy C, etc
  • Pressure: standard 2.5MPa 4MPa, customer specified pressure can be ordered,100MPa maximum
  • Wide temperature range -200°C to 350°C
  • Accurate flow measurement, up to +/- 0.1%
  • Ambient temperature range:-41~ 80°C
  • Accurate density measurement, up to +/- 0.001g/cm3
  • Repeatability:≤ ±0.05%
  • Power supply:24VDC 220VAC universal power supply, no polarity distinguish
  • Output:4~20mA 0~10KHz pulse output
  • Standard RS 485 Communication Protocol, HART Communication function
  • Available in explosion proof:Ex d ib ll C T5 Gb
  • High visibility LCD touch display
  • ANSI, GB or Jis flanges as standard, others on request



Application

  • Trade Transaction
  • Material Proportion
  • Concentration Measurement
  • Bulk Filling
  • Chemical Production Process Control
Flowma DMF-1 Series Coriolis Mass Flowmeter V-shape


Technical Indicators and Performance Parameters

Techincal Data

  • Liquid

Liquid Mass Flow / Volume Flow
Accuracy:±0.1% ±0.15% ±0.20%
Repeatability:≤ ±0.05%

  • Gas

Accuracy:±0.2% ±0.5%
Repeatability:≤ ±0.25%

  • Density Performance Indicators

Liquid Resolution:±0.0005 g/cm3 (0.5 kg/m3)
Repeatability:±0.0002 g/cm3 (0.2 kg/m3)
Measurement Accuracy:±0.002 g/cm3 (2 kg/m3)

  • Temperature Performance Indicators

Error:±0.5°C
Repeatability:±0.05°C

Temperature Measurement Range

  • Zero Stability

Flow Rate × Measurement Uncertainty(e.g 0.1%)≥Zero Stability Maximum Measurement Error(%):Measurement Uncertainty
Repeatability:±1/2× Measurement Uncertainty
Flow Rate × Measurement Uncertainty(e.g 0.1%)≤Zero Stability Maximum Measurement Error(%):± Zero Stability / Measured Value ×100%
Repeatability:±1/2 Zero Stability/ Measured Value ×100%

  • Process Temperature Effect

Medium temperature -200 ~ 150°C; -50 ~ 150°C; -50 ~ 250°C; -50 ~ 350 °C
Storage temperature -50 ~ 70°C

Factory Caliration Condition

Performance indicators are based on the working conditions (Normal 20-30°C,Pressure 0.2-0.4MPa), measured medium: water