A panel mounted oxygen analyzer with a remote sensor allows flexibility of installation. The GPR-1900 gas analyzer is suitable for trace oxygen measurements as low as 0-1 ppm; the GPR-2900 measures O2 up to 100%. The remote sensor block allows a very easy oxygen sensor replacement for simple and fast maintenance and low cost of ownership. All versions can be locked manually to a single range or auto-range. The user is always aware of the oxygen measurement range used via the range ID output.
- Measurement ranges from 0-10ppm up to 0-100% O2
- Barometric pressure and temperature compensation
- Accuracy of better than 2% of range
- Two user configurable alarms
- Range ID output
- 12-28 V DC or mains powered options
- XLT sensor options for CO2 backgrounds
GPR-1900
The favourite instrument for trace measurements as low as 0.1 ppm O2. The sensor housing is made from stainless steel to offer a high measurement integrity. The analyzer has a maximum operational range of 0-1,000 ppm but also allows the user to switch temporarily to 0-25% for calibration with ambient air in the absence of a reference gas. The GPR-1900 also displays real time ambient temperature and pressure.
Options :
- XLT sensor available.
- Ranges available: 0-10, 0-100, 0-1,000 ppm & 0-1% O2 (0-25% for calibration only)
GPR-2900
For percentage level measurements up to 100% O2 with the same features as the GPR-1900. The sensor housing is made from Delrin as standard.
Options :
- Stainless steel sensor housing.
- XLT sensor available.
- 0-100% O2 (in place of 25%).
- Ranges available: 0-1%, 0-5%, 0-10% & 0-25% O2
Features
Features
- Measurement ranges from 0-10ppm up to 0-100% O2
- Barometric pressure and temperature compensation
- Accuracy of better than 2% of range
- Two user configurable alarms
- Range ID output
- 12-28 V DC or mains powered options
- XLT sensor options for CO2 backgrounds
Applications
- Nitrogen or oxygen generators
- Glove boxes
- Oxygen injection in fish farms
- Confined space monitoring
- Sintering and other metal processing
- Delignification and bleaching in pulp & paper
Specifications
GPR-1900 | GPR-2900 | |
---|---|---|
Measurement range | 0-10, 0-100, 0-1000 ppm, 0-1%, 0-25% | 0-1%, 0-5%, 0-10%, 0-25%; optional 0-1%, 0-5%, 0-10%, 0-100% |
Accuracy | < 2% of selected range at constant conditions | |
Response time | T90 < 10 seconds | |
Recovery time | 60 seconds in air to < 10 ppm in < 1 hr on N2 purge | NA |
Sensitivity (LDL) | 0.05 ppm | 0.005% |
Linearity | < 0.5% of scale | |
Sensor model | GPR-11-60-4 XLT-11-24-4 for gases containing > 0.5% CO2 | |
Sensor life 25ÂșC (77°F) and 1 atm | 24 months in < 1000 ppm O2 6 months in air | GPR-11-60-4 60 months in air XLT-11-24-4 24 months in air |
Calibration interval | 30 days | |
Inlet pressure | 0.34 2 barg (5-30 psig) with atmospheric vent | |
Flow rate | 0.5 1.0 l/m (1-2 SCFH) | |
Gas connections | 1/8" compression tube fittings | |
Wetted parts | Stainless steel | Delrin; stainless steel optional |
Display | Graphical LCD 12.7 x 7cm (5 x 2.75”); resolution 0.001 ppm GPR-1900 MS2, 0.01 ppm GPR-1999, 0.001% GPR-2900 | |
Enclosure | Painted aluminum 6" x 4" x 4" panel mount | |
Compensation | Barometric pressure and temperature | |
Signal output | 4-20 mA or 1-5V | |
Range ID | 4-20 mA non-isolated or 1-5V Option: reassign relay contacts (eliminates standard alarms). | |
Alarms | Two user configurable alarms: magnetic coil relays rated 3A at 100 V AC | |
Operating temperature | GPR sensors: 5°C to 45°C (41°F to 113°F) XLT sensors: -10°C to 45°C (14°F to 113°F) | |
Power | 100-240 V AC or 12-28 V DC |
Download Datasheet : Analytical Industries Oxygen Analyzer with Remote Sensor
Reference : https://aii1.com/