Bamo Measures Sas has been founded in 1978. Its capital is now 400 000 Euros. Since the beginning, the company has undergone a rapid development centring on industrial pH-meters and conductivity meters. Bamo is now well-known as a leader on the French market.
Since 1990, new developments in the Level Measure have given a new spring in the export. To its own production range, the company holds numerous agencies of foreign companies in Europe and all over the world. So we are offering a complete line with always the best possible service.
Bamo is a company that comes from France. This company selling some product. The product of Bamo such as pH and ORP; Chlorine, disinfection; Data processors; Conductivity; Water hardness; Turbidity; Oxygen; Level; Temperature; Flow; Pressure; Plastic valves; Metal valves.
Temperature Programmable 2 Wires Transmitter T2FR 5333
Programmable 2 Wires Transmitter T2FR 5333 is a product from Bamo. This product come from the categories of temperature. And this temperature linear measure with resistance sensor, Pt 100, Pt 1000, Ni 100.
Features
- PT100 ohm and resistance input
- Programmable by computer
- 4/20mA or 20/4 mA
- SI EEx ia IIC, T1 -T6 in option
Application
Temperature linear measure with resistance sensor, Pt 100, Pt 1000, Ni 100. Resistance conversion to a standard 4-20mA signal (RTM) With ohmic input, it is possible to make a 60 points linearization from customer specification (specially for RTM) To avoid lost or modification of data, in case of power outage, calibration data are saved in a EEPROM. T2F5333 is delivered with configuration required by the final user. programmation on site is done by the Loop Link 5905 kit.
Another Article: |
Specification
Power supply: | non EEx: 8,0 ... 35 V |
EEx: 8,0 ...28 V | |
Internal consumption: | 25 mW ... 0,8 W |
Probe currant: | > 0,2 mA, < 0,4 mA |
Accuracy: | ± 0.3% |
Power outage: | 8 Vdc |
Response time: | from 0.33 to 60 s |
Temperature factor: | < ± 0.01 % EC / °C |
Linearity error: | < 0.1 % EC |
Power supply effect: | < 0.005 % EC / Vdc |
Line resistance | |
effect (3 wires): | < 0.002 Ohm / Ohm |
< 100°C temperature | |
Factor (RDT): | ± 0.01°C / ambiant T° |
CEM data immunity effect: | < ± 0.5 % EC |
Temp calibration: | 24°C ± 4°C |
Input max difference: | 50% of max value |
Tightness (box/terminal): | IP68 / IP00 |
Wires max section: | 1 x 1.5 mm2 |
Max. line resistance (per wire): | 10 Ohm |
Weight: | 50 g |
Download Data Sheet: Temperature Programmable 2 Wires Transmitter T2FR 5333
Ref: bamo.eu