The TCF050D pressure transmitter is suitable for measuring pressure in applications with pulsing pressure and the danger of pressure shocks and cavitation e.g. in barrel filling systems. The piezoresistive measurement cells with ceramic membrane is designed for measurement ranges from 0…1 bar to 0…100bar. The flush-mounted process connections with G1/2“ / M22x1.5 are equipped with the TCF050D pressure transmitter with diaphragm seals and stainless steel membrane. These are ideal for flush-mounting in small pipe nominal widths. High-temperature versions for constant temperatures of up to 200°C are also available. The stainless steel field housing in IP 67 and IP 69K are resistant to all common cleaning procedures.
All TCF050D series pressure transmitter are equipped with a micro-processor controlled electronics system and an accuracy of ≤ ± 0.4% FS. They are parametrised with a simple and user-friendly operating concept via 2 keys and a multi-colour status LED. They are highly suited for applications with basic requirements of functionality and exactness.
Features:
- overload-proof design especially fpr use with small pipe widths such as KEG systems
- output signal 4...20mA, Turn Down 4
- accuracy ≤ ± 0,4%FS
- standard process connections for industrial applications
- simple patametering via 2-key concept and multiple-colour status LED
- simple calibration, even without disconnection of the transmitter, through switchable power supply plant/calibrator supply
- for pressure measurement with basic requirements
- stainless-steel housings in the protection class IP 67 and IP 69K
Specification:
General details | ||||||||||||
Device type/measuring principle | TCF050D: piezoresistive | |||||||||||
Input | ||||||||||||
Measuring ranges | TCF050D | |||||||||||
Standard nominal measuring range [bar] | Relative | OP | Absolute | OP | Relative | OP | Absolute | OP | ||||
OP = overload protection [bar] | -1/0 to 1 | 2 | 0 to 1 | 2 | -1/0 to 20 | 40 | 0 to 20 | 40 | ||||
Special measuring ranges are available on request. | -1/0 to 2 | 4 | 0 to 2 | 4 | -1/0 to 50 | 100 | 0 to 50 | 100 | ||||
-1/0 to 5 | 10 | 0 to 5 | 10 | 0 to 100 | 200 | |||||||
All measurement cells are vacuum safe | ||||||||||||
-1/0 to 10 | 20 | 0 to 10 | 20 | 0 to 200 | 400 | |||||||
Recommended minimum temperature range | 2.5 bar | |||||||||||
Setting the measuring ranges | via the 2 keys within the transmitter | |||||||||||
Setting ranges | Measuring range begin | zero: | 0 to 75% | of the sensor's nominal measuring span | TD=4 | |||||||
Measuring span | span: | 25 to 100% | of the sensor's nominal measuring span | |||||||||
Burst pressure DIN16086 | >= 4-fold nominal measuring range | |||||||||||
Output | ||||||||||||
Output signal | 2-wire: 4 to 20mA with a test circuit connection in the device | |||||||||||
Fault signal | 22mA | |||||||||||
Current limitation | 3.8mA and 21mA (normal operation, cannot be set) | |||||||||||
Measuring accuracy | ||||||||||||
Reference conditions | acc. to DIN IEC 770 | |||||||||||
Linearity, hysteresis and repeatability acc. to the limit point method DIN IEC 770 | ≤ ± 0.4% of the sensor nominal measuring range | |||||||||||
Activation time | < 2 s (The device will carry out a self-test.) | |||||||||||
Setting time | < 1s | |||||||||||
Long-time drift | ≤ 0.2% of the span per year | |||||||||||
Thermal hysteresis | ≤ ± 0.2% from sensor nominal measuring range / 10K (-20...+80°C) from 4bar | |||||||||||
Conditions of use | ||||||||||||
Installation position / calibration position | Any position / standing vertically | |||||||||||
Medium temperature | G2 / G6: -40...+125°C (140°C for max. an hour) | |||||||||||
G7 / M9: -40...+200°C (high-temperature version) | ||||||||||||
Ambient storage temperature | -40...+85°C (below -20 °C danger of cable breakage) | |||||||||||
Protection class acc. to EN60529 | IP 67 and IP 69K | |||||||||||
Electromagnetic compatibility | acc.to EN 61326-1 | |||||||||||
Construction | ||||||||||||
Electrical connection | - Standard: | cable screw connection M16x1.5, nickel-plated brass (stainless steel available on request) | ||||||||||
- Optional: round plug-in connector M12x1, nickel-plated brass (stainless steel available on request) | ||||||||||||
- Optional: angle plug acc. to EN 175301-803 | ||||||||||||
- Optional: reference cable | ||||||||||||
Process connection | - All standard flush-mounted process connections and those commonly used by the manufacturer | |||||||||||
- Membrane, flush-welded on the front, CrNiSt, other materials available on request | ||||||||||||
- EPDM process seal (with a G6 process connection) | ||||||||||||
- FPM process seal (with G7 and M9 process connections) | ||||||||||||
Construction | ||||||||||||
Materials | - Field housing / lid: | CrNiSt 1.4301 (304) | ||||||||||
- Electronics cast: | Silgel | |||||||||||
- Housing seal: | FPM (Viton®) | |||||||||||
- Pressure compensation element: | Polyamide | |||||||||||
- Process connection / connection adapter: | CrNiSt 1.4404 (304) | |||||||||||
- Process membrane: | Ceramic (96% Al203) / CrNiSt 1,4435/1,4404 (316L) | |||||||||||
- Reference cable, 5-wire with reference tube: PUR (recommended: 80 m maximum) | ||||||||||||
Filling fluid | Silicon oil (FDA) | |||||||||||
Display and operation | ||||||||||||
Display | Multiple-colour status LED | |||||||||||
Operation | 2-key concept | |||||||||||
Auxiliary energy resources | ||||||||||||
Power supply / burden | 12...30V DC, max. burden: (Vsupply – 12V) / 22mA | |||||||||||
Accessories series 050D | ||||||||||||
Certificates | Calibration certificate | |||||||||||
Declaration of conformity | ||||||||||||
Material certificate acc. to EN 10204 |
Download Data Sheet: Flush-Mounted Pressure Transmitter TCF050D