Kobold DRG Rotating Vane Flowmeters

  


 

Measuring range: 0.5 - 12 ... 10 - 140 l/min water
Connection: G ⅛ ... G 1, ⅛ ... 1" NPT
Material: brass, stainless steel, polypropylene
pmax40 bar
tmax: 80°C
Accuracy: ±3 % of full scale
Pulse output, analogue output

 


 

Measuring range: 0.5 - 12 ... 10 - 140 l/min water
Connection: G ⅛ ... G 1, ⅛ ... 1" NPT
Material: brass, stainless steel, polypropylene
pmax: 40 bar
tmax: 80°C
Accuracy: ±3 % of full scale
Analogue output, digital indicator

 


 

Measuring range: 0.5 - 12 ... 10 - 140 l/min water
Connection: G ⅛ ... G 1, ⅛ ... 1" NPT
Material: brass, stainless steel, polypropylene
pmax40 bar
tmax: 80°C
Accuracy: ±3 % of full scale
Analogue output, contacts NPN / PNP, digital indicator

 


 

Measuring range: 0.5 - 12 ... 10 - 140 l/min water
Connection: G ⅛ ... G 1, ⅛ ... 1" NPT
Material: brass, stainless steel, polypropylene
pmax: 40 bar
tmax: 80°C
Accuracy: ±3 % of full scale
Pulse output, analogue output, contacts, digital indicator

 

 

Measuring range: 0.5 - 12 ... 10 - 140 l/min water
Connection: G ⅛ ... G 1, ⅛ ... 1" NPT
Material: brass, stainless steel, polypropylene
pmax: 40 bar
tmax: 80°C
Accuracy: ±3 % of full scale
Relays, analogue output, batcher, digital display

KOBOLD rotating vane flow meters series DRG are used for measuring and monitoring low viscous liquids. Series DRG flow meters are working according the well-known rotating vane principle. A magnet fitted in the vane and hermetically sealed from the medium transfers non-contacting the rotary motion to a Hall-effect sensor mounted in the housing. The sensor converts the rotary motion which is proportional to the flow to a frequency signal. A series-connected electronics unit converts the signal to an analogue output, limit contacts or display.

Fields of Application
  • Cooling water monitoring
  • Agricultural machinery
  • PCB board industry

Specifications

Technical Details

  • Material combinations: see order details in datasheet
  • Max. operating pressure: see order details in datasheet
  • Max. temperature: see order details in datasheet
  • Measuring accuracy: ±3% of full scale
  • Electrical connection: plug connector DIN 43 650, plug connector M12x1
  • Pressure loss: max. 1 bar at max. range
  • Protection: IP 65

Electronics

1. Frequency output (...F300)

  • Power supply: 12-28 VDC
  • Power consumption: 10 mA
  • Pulse output: PNP, open collector max. 25 mA
  • Electrical connection: plug connector M12x1

2. Frequency output with frequency divider

  • Power supply: 24 VDC ±20%
  • Power consumption: 15 mA
  • Pulse output: PNP, open collector, max. 25 mA
  • Electrical connection: plug connector M12x1
  • Division ratio: 1... 1/128, factory set

3. Analogue output (Option plug-on display)

  • Power supply: 24 VDC ±20%
  • Output: 0-20 mA or 4-20 mA, 2-wire or 3-wire
  • Max. load: 500 Ω
  • Electrical connection: plug connector M12x1 or DIN 43650
  • Option: plug-on display (with plug connector DIN 43650 and output 4-20 mA only), 2-wire

4. Compact electronics

  • Display: 3-segment LED
  • Analogue output: (0)4...20 mA adjustable, max. 500 W
  • Switching outputs: 1 (2) semiconductor PNP or NPN factory set
  • Contact operation: N/C / N/O contact frequency programmable
  • Setting: with 2 buttons
  • Power supply: 24 VDC ±20%, 3-wire technology approx. 100 mA
  • Electrical connection: plug connector M12x1

Download Datasheet: Kobold DRG Rotating Vane Flowmeters

Reference : kobold.com

Berbagi:  