Kobold VKM Vicositiy Compensated Flowmeter/Switch



The flowmeters and switches model VKM have a springloaded float, which slides within a cylindrical measuring tube and has an integral orifice which is believed to be unique. This and other design features means that it has for the first time become possible to create a flowmeter and switch which fully compensates for viscosity and to a large extent for density even with very low flows.

The float of these patented devices contains a permanent magnet which actuates a potential free bistable reed contact mounted outside the flow thus ensuring her-metic separation between the medium and the electrical contact system. The contact is embedded within a height-adjustable plastic housing to prevent damage to the contacts by mechanical action or aggressive atmospheres.

As the medium enters the instrument the float rises. Once its magnetic field reaches the contact tips of the reed switch the contact closes. As the flow increases the float rises further until it reaches its stop. This prevents the float from going beyond the contact range of the magnetic operating tube, that is, the contact remains closed thus ensuring bistable switching.

Viscosity Compensation

If the viscosity changes from 1 mm2/s to 540 mm2/s the indicated value is still accurate within ±5%, even with very low flows, for example, 0.1 l/min. Comparable devices, for instance conventional float-type flowmeters, are, if the viscosity changes to such an extent, subject to indicating errors up to 2500%, especially with comparable low flows. Other instruments with spring-loaded floats, which are allegedly viscosity compensated, still produce indicating errors of more than 500% with the same change in viscosity and a flow of 0.1 l/min.

Thanks to the virtually perfect viscosity compensation and good density compensation the flowmeters and switches of the latest generation are suitable both for water and highly viscous oil, without having to change the scale and without readjustment. This constitutes an extremely important advance especially in the critical area of oil lubrication circuits where measurement and switching are necessary at changing media temperatures.

  Another Article:

Features

Applications

  • Lubrication circuits
  • Hydraulics
  • Paper-making machines
  • Extruding plant
  • Machine tools
  • Printing presses
  • Oil lubrication circuits

Specifications

Technical Details

  • Body:
    VKM- x1..: brass, nickel-plated
    VKM- x2..: stainless steel 1.4301
  • Screwed fitting:
    VKM- x1..: brass, nickel-plated
    VKM- x2..: stainless steel 1.4301
  • Float:
    VKM- x1..: brass, nickel-plated
    VKM- x2..: stainless steel 1.4301
  • Orifice: stainless steel 1.4310
  • Spring: stainless steel 1.4310
  • Magnet: oxide ceramics
  • Seals:
    VKM-x1..: NBR
    VKM-x2..: FPM
  • Max. temperature: +100°C
  • Max. pressure:
    VKM- x1..: 250 bar
    VKM- x2..: 350 bar
  • Installation position: any
  • Basic accuracy: ± 4% of full scale (with a viscosity of 105 mm2/s)
  • Measuring error due to change in viscosity: for changes in viscosity within 1...540 mm2/s the additional deviation is ± 5% of full scale max.
  • Viscosity range:
    1... 540 mm2/s
    VKM-xx01 (70...400 mm2/s)

Download Datasheet: Kobold VKM Vicositiy Compensated Flowmeter/Switch

Reference : kobold.com