Analog Output Sensor FIP Series AW Lake



AW Lake is a corporate from United States of America that sell some product such as Positive Displacement Meters, Turbine Flow Meters, Tricor Coriolis Flow Meter, Lake Variable Area Flow Meter, Lake Paddle Wheel Flow Meter "Flow Stat", Monitor&Controllers, Flow Sensor & Pickup. One of the product that comes from the categories of Flow Sensor & Pickup is Analog Output Sensor FIP Series.

In the categories of Flow Sensor & Pickup there are another product such as Fiber Optic Sensor FOP-20 Series, The Edge Flow Sensor- With Bluetooth, Frequency To Analog Sensor FAC-R Series, etc.

Analog Output Sensor FIP Series

The FIP is a microprocessor based, meter mounted, analog output sensor. Each unit has a sensor, amplifier and converter module built into an aluminum junction box. The FIP is designed to handle frequencies up to 5,000 Hz. The operational frequency range is user defined via four BCD rotary switches, where the high flow rate in frequency is set to 20 mA, 5V or 10V, and the output signal is automatically scaled. Electrical connection options include ½” NPT for running conduit piping, 4-pin connector or 3-pin connector. For use with all JV-CG and JV-KG gear meters

Features:

Meter Compatibility: Used with all JV-CG and JV-KG meter

Sensor Type: Current or voltage signal output sensor

Conversion: Converts frequency to an analog output (includes sensor)

Available in six outputs: 1-5 VDC, 2-10 VDC, 4-20 mA, 0-5 VDC, 0-10 VDC, and 0-20 mA

Specification:

Supply Voltage: 10-30 VDC

Supply Current: 60 mA max

Signal Output:

  • 0-20 mA, 4-20mA or
  • 0-5V, 0-10V, 1-5V, 2-10V

Max Load Impedance: (Vcc/0.02) – 275 ohm (for mA out)

Min Load Impedance: 500 ohm (for Volt out)

Driving Capacity: For Voltage output only 10 mA max

Temperature Range: 0-185° F

Jumper Settings

J1 AB:
  • Analog Output
BC:
  • Frequency Output
J2 AB:
  • Housing Ground
CB:
  • Signal ground
Response Time:
  • 1/F + 25 msec
Frequency Input:
  • 5 KHz max
Diagnostics:
  • A glowing LED indicates the unit is working.
  • The LED will blink to show an active frequency.

Download Data Sheet: Analog output sensor FIP

Ref: aw-lake.com

Berbagi:  

Komentar

Articles