Flow Rate Transmitter AW Lake





The Flow Rate Transmitter is ideal for batching, industrial process control, mobile hydraulic equipment and computer / PLC controlled hydraulic system monitoring applications. It is designed without delicate internal components to break, abrade, or corrode. The weather tight construction includes a rugged cast aluminum enclosure built to NEMA 4X standard for installation outdoors. This variable area flow meter is used to measure air, gas, oil, and water. The transmitter provides a visual indication of flow rate that matches the transmitted output for direct reading.

Flow Rate Transmitter:

  • Simple to Install: All transmitters are factory calibrated and ship fully assembled. Simply install the transmitter into your system and apply power. No straight plumbing required at inlet or outlet.
  • Industry Standard Outputs: Transmitters provide proportional analog or pulse outputs that will drive popular data acquisition devices, meters and analog input cards.
  • Direct Reading: All transmitters provide a visual indication of flow rate that matches the transmitted output.
  • Weather-Tight Construction: The rugged cast aluminum enclosure is built to NEMA 4X standard and allows installation outdoors and in environments where liquid tight seals are required.
  • Rugged and Reliable: Without delicate internal components to break, abrade or corrode, the flow transmitter will provide many years of low-maintenance service

Features:

Measuring Accuracy: ±2.0% of full scale

14 Flow Ranges: 0.1 to 150 GPM (0.5-550 LPM), 2-1300 SCFM (1-600 SLPS)

Pressure Rating: Liquid: up to 6000 PSIG (410 bar), Air/Gas: 1000 PSIG (69 bar)

Temperature Rating: Media: 185°F (85°C) Ambient: 185°F (85°C)

Another Article:

Specification:

Measuring Accuracy: ±2.0% of full scale

Repeatability: ±1% of full scale

Flow Measuring Range:

  • 0.1-150 GPM (0.5-550 LPM)
  • 2-1300 SCFM (1-600 SLPS)

Maximum Operating Pressure:

Liquids
  • Aluminum & Brass: 3500 PSIG (240 Bar)
  • Stainless Steel: 6000 PSIG (410 Bar)
Air/Gas
  • Aluminum and brass: 600 PSIG (40 Bar)
  • Stainless steel: 1000 PSIG (69 Bar)

Maximum Operating Temperature:

  • Media: 185°F (85°C)
  • Ambient: 185°F (85°C)

Standard Calibration Fluids:

  • Oil meters: DTE 25® @ 110°F (43°C), 0.873 sg
  • Water meters: tap water @ 70°F (21°C), 1.0 sg
  • Air meters: air @ 70°F (21°C), 1.0 sg and 100 PSIG (6.8 Bar)

Filtration Requirement: 74 micron filter or 200 mesh screen minimum

Viscosity: Standard viscosities up to 110 cSt. For viscosities between 110 to 430 cSt contact factory.

Material Of Construction (Non-Wetted Components):

  • Enclosure & Cover:  Painted Aluminum
  • Seals: Buna-N®
  • Window: Pyrex®
  • Din Connector: Polyamide

Materials Of Construction (Wetted Components):

Casing & End Ports:
  • Anodized Aluminum, Brass, or Stainless Steel
Seals:
  • Anodized Aluminum: Buna-N® (STD), EPR, FKM, or Kalrez®
  • Brass: Buna-N® (STD), EPR, FKM, or Kalrez®
  • Stainless Steel 303: FKM with PTFE backup (STD), Buna-N®, EPR or Kalrez®
Transfer Magnet:
  • PTFE coated Alnico
All other internal parts: 
  • Stainless steel