The KATflow 170 flowmeter is designed around a choice of explosion-proof housings available in either offshore industry-compliant epoxy-coated copper-free aluminum, or stainless steel. The instrument is extremely easy to use and is programmed with a magnetic pen and a glass-fronted keypad for increased safety. The robustness and reliability of the KATflow 170 are further enhanced by its encapsulated IP 68 transducers which are manufactured from stainless steel and have a sturdy cable conduit.
Feature :
- Suitable for installation in hazardous areas
- Dual flow monitoring with sum, average, difference, and maximum calculations
- IP 68 stainless steel sensors as standard
- Process output options including current,open-collector, relay
- Communication options RS 485, Modbus RTU, Profibus PA, and HART* compatible output
- ATEX-certified PT100 probe for temperature compensation
Application :
- Oil and Gas :
- Oil blending skids
- Produced water measurements
- Methanol and water injection systems
- Product recognition and interface detection systems
- Coiled tubing systems
- Petrochemical :
- Measurement of refined products
- Measurement of corrosive or toxic chemicals
- Boiler feedwater measurements
- Marine and Shipbuilding :
- Tanker unloading systems
- Fire suppression systems
- Water and Wastewater: Effluent measurement in hazardous areas
- General Industry :
- Distillery process measurements
- Automated process control
- Production chemical measurements in hazardous areas
Specification :
Flow velocity range : |
0.01 ... 25 m/s |
Resolution : |
0.25 mm/s |
Repeatability : |
0.15 % of the measured value, ±0.015 m/s |
Accuracy : |
Volume flow : |
|
±1 ... 3 % of measured value depending on application |
|
±0.5 % of the measured value with process calibration |
|
Flow velocity (mean): |
|
±0.5 % of the measured value |
Turn down ratio : |
1/100 (equivalent to 0.25 ... 25 m/s) |
Measurement rate : |
100 Hz (standard) |
Response time : |
1 s (standard), 90 ms (optional) |
Damping of the displayed value : |
0 ... 99 s (selectable by user) |
The gaseous and solid content of liquid media : |
< 10 % of the volume |
Power supply : |
100 ... 240 V, AC 50/60 Hz |
Temperature range : |
-50 °C to +115 °C (-58 °F to +239 °F |
Download: Datasheet Katronic KATflow 170
For further info please contact us, sales@wmablog.com