LMag-i1 flow meter Litre Meter LMag Electromagnetic Flow Meter


The LMag-i1 flow meter incorporates the latest digital signal processing (DSP) to achieve the performance of an in-line magnetic flow meter with the flexibility and easy installation of an insertion meter.

Exceptional performance and value

Cost-effective insertion-style design provides the accuracy and reliability found in magflow meters.

Multiple outputs

Three programmable pulse outputs and one analogue output are provided with each meter.

User-friendly backlit display & user interface

‘Smart Button’ technology in the easy to read, backlit display simplifies page navigation and programming, eliminating the need for configuration tools.

Simple installation and commissioning

Factory programmed and ready for use upon delivery. All process data and programming functions are accessible via front panel display and keyboard.

Ideal for HVAC applications

Interfaces directly with your Building Management System to handle the demanding flow measurement requirements in modern HVAC management applications. Hand insertable up to 27 bar and hot tappable so system shut down is not required.

  Another Article:

Features

The LMag-i1 features a single monolithic coil designed to create a uniform magnetic field across the entire pipe, essential for accurate flow measurement in installations with less than ideal flow profiles.

  • ±1% of reading - from 0.3 to 6 m/s
  • Chilled water
  • Hot water
  • Domestic water
  • Condenser water
  • HVAC hydronic applications
  • Clean process flow applications with conductivities >25 μS/cm

Specifications

LMag-i1 Transmitter
Accuracy± 1.0% of reading from 0.3 to 6 m/s
± 0.5% of reading at the calibrated velocity
± 3 mm/s at flow rates less than 300 mm/s
Input power24 VAC40 VA @ 20 to 28 VAC
24 VDC50W @ 24 VDC ± 10%
I/O SignalsOne (1) isolated AO, 4-20 mA or 0-10 VDC
One (1) frequency
One (1) pulse
Electronics enclosureCast aluminium IP66 enclosure with display, integral mount
Display:73mm STN monochrome screen with back light, 128x64 dot matrix
Ambient conditions:-30ºC to 120ºC
ProgrammingMenu driven via four (4) programming keys
Electrical connectionsInput power:Pluggable terminal block, for use with 0.5 to 1 mm wire
I/O:Pluggable terminal block, for use with 0.4 to 0.8 mm wire

LMag-i1 Fixed insertion flow sensor

  • Performance
Sensing method:Single monolithic coil extending across entire pipe diameter
Operation:Pulsed DC coil with enhanced DSP
  • Operating Conditions
Fluid temperature range:-30ºC to 120ºC
Fluid pressure range:0 to 27 bar
Minimum conductivity:25 µS/cm
Pressure drop:Less than 35 mbar in a 6” line at 3.6m/s
  • Construction materials
Flow tube:Acetal POM/ Polysulphone
Stem assembly/electrodes:316/316L SS
Seals:EPDM
Hot tap adaptor:316/316L SS
  • Process connection
    1 inch NPT
  • Approvals
    NSF/ANSI 61
    NSF/ANSI 372

Download Datasheet: LMag-i1 flow meter Litre Meter LMag Electromagnetic Flowmeters