MaxxFlow HTC Electromagnetic Flow Meter Measurement for Dry Bulk Solids

MaxxFlow HTC Electromagnetic Flowmeter is designed for the measurement of high mass flow rates for dry bulk solids from the exit of pre-feeding devices, e. g. screw conveyors, air slides, rotary valves, bucket elevators, etc.

  • Most non-metallic solids can be measured
  • Can be installed on round pipes or ducts
  • No real upper limit of mass flow
  • Maximum pressure 10 bar
  • Dust tight
  • No flow restrictions to the process flow (wear-resistant ceramic liner)
  • The mass flow measurement is independent of flow characteristics
  • Can be installed at an angle
  • Small footprint, 220 mm (DN 100), 290 mm (DN 150), 310 mm (DN 200)
  • No moving parts, hence no maintenance
  • Easy to calibrate
  • Installation free of obstacles in the cross-section, therefore no dead spots
  • Independent of the arrangement of the line(vertical or inclined)
  • Easy retrofitting
  • Non-contact measurement procedure (no mechanics)
  • Maximum material temperature 120 °C
  • abrasion–resistant ceramic inner tube
  • maintenance-free
  • System accuracy: 0.04 %

System

A complete measuring point consists of these components:

  • Sensor for installation in the conveyor line
  • Evaluation Unit MSE 300

The sensor is available in sizes DN 70 mm, DN 100 mm, DN 150 mm, and DN 200 mm.

With the design in DN 70 mm, the connection flange could be freely selected.

The evaluation unit, in Field housing or DinRail version, is connected to the sensor using a 4-wired, shielded cable.

The maximum distance between the sensor and the evaluation unit is 300 m.

Specification

  • Sensor

Housing materialSteel St 52, powder-coated (optional stainless steel 1.4571) NW 70/100/150/200 mm,
Flange according to EN 1092-1 / PN10 DN 70: variable
Inner pipeAl2O3-Ceramic
Protection categoryIP65, ATEX: Cat. 3D
Ambient temperatureSensor pipe: - 20 ... + 120 °C
Sensor electronic: 0 ... + 60 °C
Max. working pressure1 bar
Working frequency88 kHz
Transmitting powerMax. 2 mW
WeightDepend on diameter
Accuracy± 1 ... 3 %
(based on end of measuring range and calibrated material)
System accuracy± 0.04 %
  • MSE 300-DR (DIN Rail)

Power supply24 V DC ± 10 %
Power consumption20 W / 24 VA
Protection typeIP40 to EN 60 529
Ambient operating temperature-10 ... +45 °C
Dimensions23 x 90 x 118 mm (W x H x D)
WeightApprox. 172 g
DIN rail fasteningDIN 60715 TH35
Connection terminals cable cross-section0.2 - 2.5 mm² [AWG 24-14]
Current output1 x 4 ... 20 mA (0 ... 20 mA).
load < 500
InterfaceModbus RTU (RS 485) / USB
Pulse outputOpen Collector - max. 30 V, 20 mA
Relay contactMax. rated load: 250 V AC
Max. peak current: 6 A
Max. rated load 230 V AC: 250 VA
Max. breaking capacity DC1: 3/110/220 V: 3/0.35/0.2 A
Min. switching load: 500 mW (10 V / 5 mA)
Data backupFlash Memory
  • MSE 300-FH (Field Housing)

Power supply110 / 230 V AC 50 Hz (optional 24 V DC)
Power consumption20 W / 24 VA
Protection typeIP65 to EN 60 52910.91
Ambient operating temperature-10 ... +45 °C
Dimensions258 x 237 x 174 mm (W x H x D)
WeightApprox. 2.5 kg
InterfaceRS 485 (Modbus RTU) / USB
Cable screw connectors3 x M20 (4.5 - 13 mm Ø)
Connection terminals cable cross-section0.2 - 2.5 mm² [AWG 24-14]
Current output3 x 4 ... 20 mA (0 ... 20 mA), load < 500 Ω (Active)
Pulse outputOpen Collector - max. 30 V, 20 mA
Relay contactMax. rated load: 250 V AC
Max. peak current: 6 A
Max. rated load 230 V AC: 250 VA
Max. breaking capacity DC1: 3/110/220 V: 3/0.35/0.2 A
Min. switching load: 500 mW (10 V / 5 mA)
Data backupFlash Memory

Reference: swr-engineering.com