Fluke 922 Micromanometer/Air Flow Meter

The Fluke 922 makes airflow measurements easy by combin-ing pressure, air flow, and velocity into a single, rugged meter. Compatible with most pitot tubes, the Fluke 922 allows technicians to conve-niently enter their duct shape and dimensions for maximum measurement accuracy.

The Fluke 922 Airflow Meter helps you:
  • Monitor air pressure across key HVAC components
  • Ensure proper air flow balance
  • Promote good indoor air quality
  • Maintain a comfortable environment

Use the Fluke 922 to:
  • Measure pressure drops across filters and coils
  • Match ventilation to occupant loads
  • Monitor indoor vs. outdoor pressure relationships and manage the building envelope
  • Perform duct traversals for accurate airflow readings

Features:

  • Powerful meter provides differential and static pres-sure, air velocity and flow readings
  • Rugged design built for field use
  • Easy to use without sacrific-ing performance
  • User-defined duct shape and size for maximum airflow accuracy
  • Convenient colored hoses help you properly diagnose pressure readings
  • Bright, backlit display for clear viewing in all environments
  • Min/Max/Average/Hold func-tions for easy data analysis
  • Auto power off saves battery life

Specification:

  • Operating

FeatureRangeResolutionAccuracy
Air Pressure± 4000 Pascals
± 16 in H2O
± 400 mm H2O
± 40 mbar
± 0.6 PSI
1 Pascal
0.001 in H2O
0.1 mm H2O
0.01 mbar
0.0001 PSI
± 1 % + 1 Pascal
± 1 % + 0.01 in H2O
± 1 % + 0.1 mm H2O
± 1 % + 0.01 mbar
± 1 % + 0.0001 PSI
Air Velocity250 to 16,000 fpm
1 to 80 m/s
1 fpm
0.001 m/s
± 2.5 % of reading at 2000 fpm (10.00 m/s)
Air Flow (Volume)0 to 99,999 cfm
0 to 99,999 m3/hr
0 to 99,999 l/s
1 cfm
1 m3/hr
1 l/s
Accuracy is a function of velocity and duct size
Temperature0 °C to 50 °C
32 °F to 122 °F
0.1 °C
0.1 °F
± 1 % + 2 °C
± 1 % + 4 °F
  • General Specifications

Operating Temperature0 °C to +50 °C (+32 °F to +122 °F)
Storage Temperature-40 °C to +60 °C (-40 °F to +140 °F)
Operating Relative Humidity0 % to 90 %, non-condensing
IP RatingIP40
Operating Altitude2000 m
Storage Altitude12000 m
EMI, RFI, EMCMeets requirements for EN61326-1
VibrationMIL-PREF-28800F, Class 3
Max Pressure at Each Port10 PSI
Data Storage99 readings
PowerFour AA batteries
Typical Battery Life375 hours without backlight, 80 hours with backlight

Model Completeness

  • Fluke-922 Airflow Meter : Fluke 922 Airflow Meter, Two Rubber Hoses, Wrist Strap, Four AA Batteries 1.5 V Alkaline, Users Manual and Soft Carrying Case
  • Fluke-922/Kit Airflow Meter : Fluke 922 Airflow Meter, 12 in. pitot tube, ToolPakTM, Two Rubber Hoses, Wrist Strap, Four AA Batter-ies 1.5 V Alkaline, Users Manual and Hard Carrying Case
  • PT12 : Pitot Tube, 12 in
Berbagi:  