Case Drain Flow Meter AW Lake

AW Lake is a corporate from United States of America that sell some product such as Positive Displacement Meters, Turbine Flow Meters, Tricor Coriolis Flow Meter, Lake Variable Area Flow Meter, Lake Paddle Wheel Flow Meter "Flow Stat", Monitor&Controllers. One of the product that comes from the categories of Lake Variable Area Flow Meter is Case Drain Flow Meter.

Case Drain Flow Meter

The Case Drain Flow Meter is a Variable Area Flow Meter offering a low cost alternative for monitoring pump performance and identifying required maintenance without interrupting operation. This meter is available for oil or water flow measurement.

The superior exterior design of this flow measurement solution is weather-tight for use in outdoor environments and in systems with wash-down requirements. Case Drain Flow Meter is a low cost alternative for monitoring pump performance and identifying required maintenance.

Advantages:

  • Unrestricted Mounting: Allows for horizontal, vertical or inverted installation and does not require straight plumbing on inlet or outlet.
  • Superior Exterior Design: Weather-tight for use outdoors and/or on systems where wash-downs are required.
  • Rugged and Reliable: These meters are constructed with all metal pressure vessels that allow safe and permanent installation.
  • Multiple Ports Available: Standard selection of NPT, SAE and BSPP ports reduces the amount of adapters required for installation.

Features:

  • Measuring Accuracy: ±5% of full scale
  • Flow Measuring Range: 0.1-30 GPM (0.5-115 LPM)
  • Maximum Operating Pressure: 1000 PSIG (69 Bar)
  • Maximum Operating Temperature: 240°F (116°C)

Another Article:

Specification:

Measuring Accuracy: ±5.0% of full scale

Repeatability: ±1% of full scale

Flow Measuring Range: 0.1-30 GPM (0.5-115 LPM)

Maximum Operating Pressure: 1000 PSIG (69 Bar)

Maximum Operating Temperature: 240°F (116°C)

Standard Calibration Fluids:

  • Oil meters: DTE 25® @ 110°F (43°C), 0.873 sg
  • Water meters: tap water @ 70°F (21°C), 1.0 sg

Filtration Requirement: 74 micron filter or 200 mesh screen minimum

Materials Of Construction: (Non-Wetted Components):

  • Window Tube: Polycarbonate
  • Window Seals: Buna-N

Materials Of Construction (Non-Wetted Components):

  • Casing: Anodized Aluminum
  • End Ports: Non-Anodized Aluminum
  • Seals: Buna-N
  • Transfer Magnet: PTFE coated Alnico
  • All other internal parts: Stainless steel

Download Data Sheet: Case Drain Flow Meter

Ref: aw-lake.com