The PZM pressure transmitters are suitable for taking pressure and filling level measurements in pipelines and containers. The modular process connection system offers a wide range of connection adapters and helps to cut costs in the long term. The flush-mounted process connection with O-ring seal and stainless steel membrane is certified to EHEDG type EL-ASEPTIC CLASS 1 and is thus predestined for measurements which satisfy even the most stringent hygiene requirements. The sensor measuring ranges of the piezoresistive vacuum-proof measuring cell with stainless steel membrane of the PZM pressure transmitters range from -1/0…0.35bar to -1/0…100bar.
Special measuring ranges are possible for both versions. All the pressure transmitters in series 100/101 are designed for universal applications and, in particular, for applications with constantly high temperatures of up to 200°C. Furthermore, using the on-site display with series 100 and the display and operating module OPUS M in series 101, the pressure transmitters can be simply read out, configured and diagnosed.
Features:
- EHEDG-aseptic certified modular process connection system
- precise measurements ≤ ± 0,15% FS
- Turn Down 10
- integrated or external display and operating module OPUSM
- vacuum proof and extremely overload safe
- direct entry of parameters with plain text display
- easy to clean and high protection classes IP 67 and IP69K
- application strengths: content and process pressure measurements / vacuum measurements even at high temperatures
Specification:
General details | |||||||||||||
Device type / measuring principle | PZM 100/101: piezoresistive | ||||||||||||
VRM 100/101: capacitive | |||||||||||||
Input | |||||||||||||
Measuring ranges | PZM 100/101 | VRM 100/101 | |||||||||||
Standard nominal measuring range [bar] | relative | OP | absolute | OP | relative | OP | absolute | OP | |||||
OP = overload protection [bar] | 0...0.35 | 1 | -1/0...4 | 25 | 0...4 | 25 | |||||||
0...1 | 3 | 0...1 | 3 | -1/0...10 | 40 | 0...10 | 40 | ||||||
-1/0...2.5 | 8 | 0...2.5 | 8 | -1/0...20 | 40 | 0...20 | 40 | ||||||
Special measuring ranges are available on request. | -1/0...5 | 15 | 0...5 | 15 | -1/0...40 | 60 | 0...40 | 60 | |||||
-1/0...10 | 30 | 0...10 | 30 | -1/0...70 | 105 | 0...70 | 105 | ||||||
-1/0...30 | 90 | 0...30 | 90 | ||||||||||
All measuring cells are vacuum-proof | |||||||||||||
-1/0...100 | 250 | 0...100 | 250 | ||||||||||
Setting the measuring ranges | Via the keypad of the OPUSM display and operating module / via the integrated on-site display | ||||||||||||
Setting ranges | Start the measuring zero: | 0...90% of the sensor's nominal measuring span | TD=10 | ||||||||||
Measuring span: | 10...100% of the sensor's nominal measuring span | ||||||||||||
Burst pressure DIN16086 | ≥ 4-fold measuring range | ||||||||||||
Output | |||||||||||||
Output signal | 2-wire: 4...20mA with a test circuit connection in the device | ||||||||||||
Fault signal | Optional: 3.8mA, 22mA, hold (i.e. holding the last value) | ||||||||||||
Current limitation | 3.85mA and 21.5mA (normal operation) | ||||||||||||
Integration time | Continuously selectable between 0 and 300s (setting time after a pressure leap) | ||||||||||||
Measuring accuracy | |||||||||||||
Reference conditions | acc. to DIN IEC 770 | ||||||||||||
Linearity, hysteresis and repeatability as per the limit point method DIN IEC 770 | ≤ ± 0.15% of the sensor's nominal measuring range | ||||||||||||
DIN IEC 770 | |||||||||||||
Activation time | < 5s (the device will carry out a self-test.) | ||||||||||||
Setting time (without damping) | < 200ms | ||||||||||||
Long-time drift | ≤ 0.2% of the span per year | ||||||||||||
Thermal hysteresis | ≤ ± 0.75% beginning of the measuring range / ≤ ± 0.8% end of the measuring range (VRM) | ||||||||||||
≤ ± 0.2% of the sensor's nominal measuring range / 10K (-20...+80°C) from 4 bar (PZM) | |||||||||||||
≤ ± 0.3% of the sensor's nominal measuring range / 10K (-20...+80°C) up to 0.6 bar (PZM) | |||||||||||||
Conditions of use | |||||||||||||
Installation position / calibration position | Any position / standing vertically | ||||||||||||
Medium temperature | PZM: | T1: | -40...+125°C (140°C over one hour at the most) | ||||||||||
T2: | -40...+200°C (high-temperature version) | ||||||||||||
VRM: | -40...+140°C | ||||||||||||
Ambient storage temperature | Type 101: | -40...+85°C | |||||||||||
Type 100: | -30...+75°C | ||||||||||||
(Below -20°C cable breakage might occur and the display's function may be impaired.) | |||||||||||||
Protection class acc. to EN60529 | IP 67 and IP 69K | ||||||||||||
Electromagnetic compatibility | Sensitivity against interference: acc. to DIN IEC 61000-6-2 | ||||||||||||
Interference radiation: | acc. to DIN IEC 61000-6-4 | ||||||||||||
Construction | |||||||||||||
Electrical connection | - Standard: cable screw connection M16x1.5, nickel-plated brass, stainless steel available on request | ||||||||||||
- Optional: round plug-in connector M12x1, nickel-plated brass, stainless steel available on request | |||||||||||||
- Optional: angle plug acc. to EN 175301-803 | |||||||||||||
- Optional: reference cable | |||||||||||||
Process connection | - Membrane, flush-welded on the front, CrNiSt, other materials available on request | ||||||||||||
- EHEDG type EL-ASEPTIC CLASS 1, certified connection system PZM / VRM | |||||||||||||
with press screw M38x1.5 and elastomer sealing | |||||||||||||
- Process seal EPM (FDA) (temperature range: -20...+150°C) | |||||||||||||
- Process seal FPM (FDA) (temperature range: -40...+200°C) | |||||||||||||
Materials | - Field housing / lid: | CrNiSt 1.4301 (304) | |||||||||||
- Housing seal: | FPM (Viton®) | ||||||||||||
- Pressure compensation element: | polyamide | ||||||||||||
- Inspection gauge (type 100): | polycarbonate | ||||||||||||
- Process connection / connection adapter: | CrNiSt 1.4404 (316L) | ||||||||||||
- Process membrane: | CrNiSt 1.4435/1.4404 (316L) | ||||||||||||
- Locking screw (type 101): | CrNiSt 1.4301 (304) | ||||||||||||
- Reference cable: 5-wire with reference tube: PUR (recommended: 80m maximum) | |||||||||||||
Filling fluid | PZM: | silicon oil (FDA) | |||||||||||
VRM: | medical mineral oil (FDA) | ||||||||||||
Display and operation | |||||||||||||
Display | LCD, 4-digit numerical display and 5-digit alphanumerical display | ||||||||||||
Type 100: | integrated on-site display (cannot be separated from device) | ||||||||||||
Type 101: | external OPUSM display and operating module | ||||||||||||
Displayable units | Pressure: | mbar, bar, psi, Pa, mH2O, mmHg, Torr, atm, at, kg/cm² | |||||||||||
Temperature*1: | °C, °F, K, °R, °RĂ© | ||||||||||||
Additional displays | Output current in mA or % (in relation to the span) | ||||||||||||
Operation | 100:00:00 | via the configuration menu with the integrated on-site display | |||||||||||
101:00:00 | via the configuration menu with the external OPUSM display and operating module | ||||||||||||
Auxiliary energy resources | |||||||||||||
Power supply / burden | 12-36V DC, max. burden: (Vsupply – 12V) / 24mA | ||||||||||||
Accessories 100 series | |||||||||||||
OPUSM display and operating module | External display and operating module, CrNiSt, IP 67, 41x70mm, 1m connection cable and round plug-in | ||||||||||||
connector M12x1 | |||||||||||||
Certificates | Calibration certificate | ||||||||||||
Declaration of conformity | |||||||||||||
Material inspection certificates as per EN 10204 | |||||||||||||
EHEDG certificate |