The ceramic-sensor-based, flush-mounted pressure transmitters with metal membrane – Type TCS – for relative and
absolute pressure with various sensor elements are available with manometer connection or flush-mounted membrane. This connecting concept allows highly overload-resistant pressure measurements and provides high operating safety for industrial process pressure and level measurements.
The devices are cast into stainless steel standard housings and are available according to protection types from IP65
onwards. High-temperature versions for continuous operation at up to 200 ºC are available. Vacuum-resistance guaranteed. Installation into pipes with small nominal diameters is easily possible, due to the compact design.
Appropriate welding sockets and process adaptors can be ordered. The two process connection variants are G ½ or M22x1.5 with a threaded connection. In addition to the standard housing, a field housing design can be selected.
Features:
- high overload safety for flush mounted applications with o-ring seal
- measuring ranges from 0...2 bar to 0...400 bar for relative and absolute pressure in standard design
- high-temperature safe up to 200ºc continuous load
- shock- and vibration-resistant
- different process connection adaptors
Specification:
Applications | Absolute and relative pressure measurement in gases, vapours and liquids | ||||||||||||||||||||
Measuring principle | The process pressure acts on the metallic separation membrane of the sensor and is transmitted to the resistance bridge via the filling liquid. The change in output voltage proportion to the pressure is measured. | ||||||||||||||||||||
Input | |||||||||||||||||||||
Measuring ranges (depending on type of device) | Relative pressure | Absolute pressure | |||||||||||||||||||
relative | ÃœSI | relative | ÃœSI | absolute | ÃœSI | absolute | ÃœSI | ||||||||||||||
Nominal measuring ranges (bar) | 2 | bar | 5 | 100 | bar | 250 | 2 bar | 5 | 200 bar | 500 | |||||||||||
ÃœSI = Overload protection (bar) | 2.5 | bar | 8 | 200 | bar | 500 | 5 bar | 12 | 400 bar | 600 | |||||||||||
5 | bar | 12 | 400 | bar | 600 | 10 bar | 25 | ||||||||||||||
10 | bar | 25 | 20 bar | 50 | |||||||||||||||||
20 | bar | 50 | 50 bar | 120 | |||||||||||||||||
50 | bar | 120 | 100 bar | 250 | |||||||||||||||||
Adjustable ranges | Measuring span ± 20% | ||||||||||||||||||||
Zero point | ± 20% | ||||||||||||||||||||
Output | |||||||||||||||||||||
Output signal | 4...20 mA, 2-wire circuit | ||||||||||||||||||||
Working resistance | Rb (2-wire) | ≤ | Us - 13 V | Us = supply voltage | |||||||||||||||||
0.02 A | Rb = working resistance | ||||||||||||||||||||
Breakdown signal | typical 34 mA, max. 40 mA | ||||||||||||||||||||
Measuring accuracy | |||||||||||||||||||||
Reference conditions | According to. EN 60751, | Ta = 20°C | |||||||||||||||||||
Linearity | ≤ ± 0.4% of the set measuring range, limit point method according to DIN IEC 770 | ||||||||||||||||||||
Warm-up time | 1 s | ||||||||||||||||||||
Rise time | ≤ 10 ms (without attenuation) | ||||||||||||||||||||
Long-term drift | ≤ 0.4% relative to the initial measuring range | ||||||||||||||||||||
Temperature coefficient | ± 0.4% FS / 10 K for zero point, compensation range 0...70°C | ||||||||||||||||||||
± 0.2% FS / 10 K for measuring range | |||||||||||||||||||||
Effect of vibration | 1.5 mm (10...55 Hz) | ||||||||||||||||||||
Installation position | Vertical (above 4 bar no restrictions) | ||||||||||||||||||||
Conditions for use | |||||||||||||||||||||
Medium temperature | -40°C... + 125°C, 140°C max. for 1 h (type HT for temperatures up to 200°C) | ||||||||||||||||||||
Environmental temperature | -40°C... + | 85°C | |||||||||||||||||||
Storage temperature | -40°C... + | 85°C | |||||||||||||||||||
Protective type acc. to EN 60529 | - IP 65 (with plug connection acc. to EN 175301-803) | ||||||||||||||||||||
0 | (with permanently attached reference cable or M12x1 plug) | ||||||||||||||||||||
Electromagnetic compatibility | EMC directives according to EN 50081-2 / 50082-2 are fulfilled, | CE-sign | |||||||||||||||||||
Design configuration | |||||||||||||||||||||
Type | VA rod housing and process connections, flush-mounted | ||||||||||||||||||||
Material | - Standard housing made of 1.4301 | ||||||||||||||||||||
- Process connections made of 1.4404 | |||||||||||||||||||||
Electrical connection | - | Standard: Plug connection acc. to EN 175301-803 | |||||||||||||||||||
- optional: Permanently connected reference cable, length 1 m | |||||||||||||||||||||
- | optional: | Round plug M12 x 1 | |||||||||||||||||||
Filling liquid | Silicon oil (suitable for food products, FDA), white oil (FDA) | ||||||||||||||||||||
Auxiliary energy | |||||||||||||||||||||
Supply voltage | 13...30 DC, max. permissible residual ripple 1 Vss | ||||||||||||||||||||
Supply voltage effect | ≤±0.03% |
Download Data Sheet: Flush-Mounted Pressure Transmitter TCS Type