Flush-Mounted Pressure Transmitter VRM050D Series Hengesbach



The VRM050D pressure transmitter is suitable for measuring the pressure and filling level in pipes. The highly overload safe capacitative measuring cells and the diaphragm seal makes the VRM050D ideal for use in applications with pressure shocks or cavitations such as in separators. Measuring ranges from -1/0…4bar to -1/0…70bar and special measuring ranges are available. The robust construction of the stainless steel field housing in IP 67 and IP 69K withstand aggressive and residue-free cleaning procedures such as those required in the food industry. All 050D series pressure transmitter are equipped with a micro-processor controlled electronics system and an accuracy of ≤ ± 0.2% FS. They are parametrised with a simple and user-friendly operating concept via 2 keys and a multi-colour status LED. They are highly suited for applications with basic requirements of functionality and exactness.

As a process connection, the VRM050D comes equipped with a PZM modular system and is highly suited for applications placing the highest requirements of hygiene. The modular system PZM is certified according to EHEDG type EL-Aseptic Class I and is impermeable to micro-organisms.. The large range of process connection adapters such as the welded-in lugs for pipes, VARIVENT®, DRD flanges, DIN 11851 conical couplings, DIN 32676 clamps, etc. mean that the pressure transmitters can be used for a wide range of uses.

Features:

  • special construction of the measuring cell an process connection for systems with pressure shocks and vibration e.g. separators, ...
  • EHEDG-aseptic certified modular process connection system PZM
  • accuracy ≤ ± 0,2%FS
  • simple calibration, even without disconnection of the transmitter, through switchable power supply plant/calibrator supply
  • output signal 4...20mA, Turn Down 4
  • simple patametering via 2-key concept and multiple-colour status LED
  • capacitive measuring cell, vacuum and overload safe, stainless steel membrane
  • easy to clean and high protection class IP 67 and IP 69K

Specification:

General details

          
Device type/measuring principleVRM050D: capacitive       

Input

          
Measuring ranges    VRM050D   
Standard nominal measuring range [bar] Relative OPRelative OPAbsolute OP
OP = overload protection [bar] 4 25-1 to 4 254 25
  10 40-1 to 10 4010 40
Special measuring ranges are available on request. 20 40-1 to 20 4020 40
  40 60-1 to 40 6040 60
All measurement cells are vacuum safe          
 70 105-1 to 70 10570 105
Setting the measuring rangesvia the 2 keys within the transmitter     
Setting rangesMeasuring range begin zero:0 to 75%of the sensor's nominal measuring spanTD=4
 Measuring spanspan:25 to 100%of the sensor's nominal measuring span 
Burst pressure DIN16086>= 4-fold nominal measuring range     

Output

          
Output signal2-wire:   4 to 20mA with a test circuit connection in the device   
Fault signal22mA       
Current limitation3.8mA and 21mA (normal operation, cannot be set)   

Measuring accuracy

          
Reference conditionsacc. to DIN IEC 770       
Linearity, hysteresis and repeatability acc. to the limit point method DIN IEC 770≤ ± 0.2% of the sensor nominal measuring range   
           
Activation time< 2 s (The device will carry out a self-test.)     
Setting time< 1s       
Long-time drift≤ 0.2% of the span per year      
Thermal hysteresis0.2% of the sensor nominal measuring range / 10K (-20...+80°C) from 4 bar 
 0.3% of the sensor's nominal measuring range / 10K (-20 to +80°C) up to 0.6 bar 

Conditions of use

          
Installation position / calibration positionAny position / standing vertically      
Medium temperature-40...+140°C       
Ambient storage temperature-40...+85°C (below -20 °C danger of cable breakage)   
Protection class acc. to EN60529IP 67 and IP 69K       
Electromagnetic compatibilityacc.to EN 61326-1       

Construction

          
Electrical connection- Standard:  M16x1.5 cable screw connection, nickel-plated brass (stainless steel available on request)
- Optional:  M12x1 round plug-in connector, nickel-plated brass (stainless steel available on request)  
           
- Optional:  angle plug acc. to EN 175301-803      
           
- Optional:  reference cable       
           
Process connectionMembrane, flush-welded, CrNiSt (other materials available on request)        
 - EHEDG type EL-ASEPTIC CLASS I, certified connection system PZM /        
 with M38x1.5 press screw and elastomer sealing        
 - EPM process seal (FDA conform) (range -20...+150°C)        

Construction

          
Materials- Field housing / lid:CrNiSt 1.4301 (304)        
 - Electronics cast:Silgel        
 - Housing seal:FPM (Viton®)        
 - Pressure compensation element:Polyamide        
 - Process connection / connection adapter:CrNiSt 1.4404 (304)        
 - Process membrane:CrNiSt 1.4435/1.4404 (316L)        
 - Reference cable, 5-wire with reference tube:  PUR (recommended: 80 m maximum)        
Filling fluidMedical mineral oil (FDA)         

Display and operation

          
DisplayMultiple-colour status LED         
Operation2-key concept         

Auxiliary energy resources

          
Power supply / burden12...30V DC, max. burden: (Vsupply - 12V) / 22mA         
           
CertificatesCalibration certificate         
 Declaration of conformity         
 Material certificate acc. to EN 10204         
 EHEDG certificate         

Download Data Sheet: Flush-Mounted Pressure Transmitter VRM050D