The TPF050D pressure transmitter is suitable for measuring of the pressure and filling level in pipes and tanks, even with small nominal diameters. Depending on the process connection, the flush-mounted measuring cell with stainless steel membrane enables measuring ranges of -1/0…0.35bar to -1/0…100bar. The robust stainless steel field housing and the checked protection classes IP 67 and IP 69K withstand all aggressive and residue-free cleaning procedures such as those required in the food and pharmaceuticals industry.
The 050D series pressure transmitters are equipped with a micro-processor controlled electronics system and an accuracy of ≤ ± 0.2% FS. They are parametrised with a simple and user-friendly operating concept via 2 keys and a multi-colour status LED. A TurnDown of up to 4 can be set using the full and empty adjustment. A wide range of hygienic and non-hygienic process connections is available for the TPF050D. The process connection adapters available include: ISO 228 G1“ screw-in threads with an elastomer-free sealing cone and press screw, conical couplings or DIN 11851, VARIVENT® with Ø 50mm or Ø 68mm, DRD. Customer-specific solutions are also possible.
Features:
- output signal 4...20mA, TURNDOWN 4
- accuracy ≤ ± 0,2%FS
- simple calibration, even without disconnection of the transmitter, through switchable power supply plant / calibrator supply
- with hygienic and standard process connections as a fixed connection
- simple parametering via 2-key concept and multi-colour status-LED
- vacuum and overload safe
- for measurement of pressure and filling level in tanks and pipes with basic requierments
- easy to clean and high protection classes IP 67 und IP 69K
Specification:
General details | ||||||||||||
Device type/measuring principle | TPF050D: piezoresistive | |||||||||||
Input | ||||||||||||
Measuring ranges | TPF050D | |||||||||||
Standard nominal measuring range [bar] | Relative | OP | Absolute | OP | Relative | OP | Absolute | OP | ||||
OP = overload protection [bar] | 0 to 0.35 | 1 | -1/0 to 10 | 30 | 0 to 10 | 30 | ||||||
Special measuring ranges are available on request. | 0 to 1 | 3 | 0 to 1 | 3 | -1/0 to 30 | 90 | 0 to 30 | 90 | ||||
-1/0 to 2.5 | 8 | 0 to 2.5 | 8 | -1/0 to 100 | 250 | 0 to 100 | 250 | |||||
-1/0 to 5 | 15 | 0 to 5 | 15 | |||||||||
All measurement cells are vacuum safe | ||||||||||||
Setting the measuring ranges | via the 2 keys within the transmitter | |||||||||||
Setting ranges | Measuring range begin | zero: | 0 to 75% | of the sensor's nominal measuring span | TD=4 | |||||||
Measuring span | span: | 25 to 100% | of the sensor's nominal measuring span | |||||||||
Burst pressure DIN16086 | >= 4-fold nominal measuring range | |||||||||||
Output | ||||||||||||
Output signal | 2-wire: 4 to 20mA with a test circuit connection in the device | |||||||||||
Fault signal | 22mA | |||||||||||
Current limitation | 3.8mA and 21mA (normal operation, cannot be set) | |||||||||||
Measuring accuracy | ||||||||||||
Reference conditions | acc. to DIN IEC 770 | |||||||||||
Linearity, hysteresis and repeatability acc. to the limit point method DIN IEC 770 | ≤ ± 0.2% of the sensor nominal measuring range | |||||||||||
Activation time | < 2 s (The device will carry out a self-test.) | |||||||||||
Setting time | < 1s | |||||||||||
Long-time drift | ≤ 0.2% of the span per year | |||||||||||
Thermal hysteresis | ≤ | 0.2% of the sensor's nominal measuring range / 10K (-20 to +80°C) from 4 bar | ||||||||||
≤ | 0.3% of the sensor's nominal measuring range / 10K (-20 to +80°C) up to 0.6 bar | |||||||||||
Conditions of use | ||||||||||||
Installation position / calibration position | Any position / standing vertically | |||||||||||
Medium temperature | T1: | -40 °C to +125 °C (140 °C for max. an hour) | ||||||||||
T2: | -40...+200°C (high-temperature version) | |||||||||||
Ambient storage temperature | -40...+85°C (below -20 °C danger of cable breakage) | |||||||||||
Protection class acc. to EN60529 | IP 67 and IP 69K | |||||||||||
Electromagnetic compatibility | acc.to EN 61326-1 | |||||||||||
Construction | ||||||||||||
Electrical connection | - Standard: | M16x1.5 cable screw connection, nickel-plated brass (stainless steel available on request) | ||||||||||
- Optional: M12x1 round plug-in connector, nickel-plated brass (stainless steel available on request) | ||||||||||||
- Optional: angle plug acc. to EN 175301-803 | ||||||||||||
- Optional: reference cable | ||||||||||||
Process connection | - All standard flush-mounted process connections and those commonly used by the manufacturer | |||||||||||
- Membrane, flush-welded on the front, CrNiSt, other materials available on request | ||||||||||||
Construction | ||||||||||||
Materials | - Field housing / lid: | CrNiSt 1.4301 (304) | ||||||||||
- Electronics cast: | Silgel | |||||||||||
- Housing seal: | FPM (Viton®) | |||||||||||
- Pressure compensation element: | Polyamide | |||||||||||
- Process connection / connection adapter: | CrNiSt 1.4404 (304) | |||||||||||
- Process membrane: | CrNiSt 1.4435/1.4404 (316L) | |||||||||||
- Reference cable, 5-wire with reference tube: | PUR (recommended: 80 m maximum) | |||||||||||
Filling fluid | Silicon oil (FDA) | |||||||||||
Display and operation | ||||||||||||
Display | Multiple-colour status LED | |||||||||||
Operation | 2-key concept | |||||||||||
Auxiliary energy resources | ||||||||||||
Power supply / burden | 12...30V DC, max. burden: (Vsupply – 12V) / 22mA | |||||||||||
Accessories 050D | ||||||||||||
Certificates | Calibration certificate | |||||||||||
Declaration of conformity | ||||||||||||
Material certificate acc. to EN 10204 |