VTC/VIC Kem Kuppers Local Displays





Compact on-site display with carrier frequency or inductive sensor for the evaluation of volume flows.

A temperature sensor integrated into the sensor tip is available in the VTC version, thereby making it possible to measure the medium temperature.

All measurement results and parameters relevant for the process can be shown directly on the VTC/VIC via the graphic display (that can be illuminated) and changed using the four membrane keys.

3 linearization banks with 20 points each are available to improve the accuracy. They are used to linearize the measurement signal depending on the chosen operating mode (external control, fixed assignment).

In pure 2-conductor operation (4 - 20 mA) the instantaneous value (flow) is dimensionally output on the current loop according to the programming.

A programmable digital output and a maximum of two control inputs (see technical data) are available in addition for further processing and control.

The VTC/VIC has an interface that allows operating parameters to be set and measured values to be read with the help of the CON.USB interface adapter and the “KEM EasyControl” visualization software. Optionally this interface can also be carried out as HART or USB.

Depending on the version, the electrical connection is realized via a plug connector or a screw terminal strip that is exposed when the front cover is flipped open.

  Another Article:

Features

Applications (depending on version)

  • Ex-Approval
  • 360° turnable housing
  • Temperature measurement
  • 3 x 20 points linearisation
  • Graphic display
  • Fast setup
  • Integrated interface
  • Programming and visualisation via KEM „Easy Control“ possible
  • Setting of operation type
  • Normalized frequency output
  • Control inputs
  • 2 Status-LEDs

Specifications

Technical Data

  • Carrier frequency or inductive pickup
  • Analog Output: 4 - 20 mA passive (2 wire)
  • Frequency output, freely scalable, Push Pull or NAMUR
  • 20 point linearization of the measured value, 3 banks
  • Control input
  • KEM interface (standard) or USB or HART
  • Ex Protection: ATEX Ex II 2G Ex ia IIC T4 Gb

Download Datasheet: VTC/VIC Kem Kuppers Local Displays